PROCESS CONTROL | Drying purpose | Wood | Wood | Wood | Wood | Wood |
| Drying mode | Automatic, semi-automatic or manual | Automatic, semi-automatic or manual | Automatic, semi-automatic or manual | Automatic, semi-automatic or manual | Automatic, semi-automatic or manual |
| Drying type | Conventional, dehumidifying (condensation) and combined drying | Conventional, dehumidifying (condensation) and combined drying | Conventional drying | Conventional drying | Dehumidifying (condensation) and combined drying |
| Drying regimes | 60 | 60 | 60 | 60 | 60 |
| Time-based regimes |  |  |  |  |  |
| Possibility to change the basic regimes for drying wood |  |  |  |  |  |
| Wood thickness | 20 ÷ 80 mm | 20 ÷ 80 mm | 20 ÷ 80 mm | 20 ÷ 80 mm | 20 ÷ 80 mm |
| Start / stop / pause function |  |  |  |  |  |
| Automatic conditioning |  |  |  |  |  |
| Automatic equalization |  |  |  |  |  |
| Wood heat treatment |  |  |  |  |  |
HOUSING | Aluminum |  |  |  |  |  |
| Plastic |  |  |  |  |  |
INPUTS | Wire connection of probes | max 300 m, remote (via MKM-08) | max 300 m, remote (via MKM-08) | max 300 m, remote (via MKM-08) | max 30 m, locally | max 30 m, locally |
| Wireless connection of probes | remote (via MKM-RF) | / | / | / | / |
| Number of inputs for temperature measurement | 2 | 2 | 2 | 1 | 1 |
| Number of inputs for measuring equilibrium humidity | 2 | 2 | 2 | 1 | 1 |
| Number of inputs for measuring moisture in wood | 8 | 8 | 8 | 4 | 4 |
| Control inputs for temperature measurement | 3 | 1 | 1 | 1 | 1 |
| Number of digital inputs | 5 | 4 | 2 | 3 | 3 |
OUTPUTS | Heating | PID or ON/OFF | PI or ON/OFF | ON/OFF | ON/OFF | ON/OFF |
| Circulation pump |  |  |  |  |  |
| Drying | PID or ON/OFF | PI or ON/OFF | PI or ON/OFF | PI or ON/OFF | ON/OFF |
| Cooling | PID or ON/OFF | ON/OFF | / | / | / |
| Fans |  |  |  |  |  |
| Frequency converters for fans |  |  |  |  |  |
| Humidification |  |  |  |  |  |
| Recuperator |  |  |  |  |  |
| Frequency converters for recuperator |  |  |  |  |  |
| Compressor |  |  |  |  |  |
| Relay output for alarm |  |  |  |  |  |
| Connecting to a computer (standard RS485) |  |  |  |  |  |
OTHERS | Parameter protection against unauthorized changes |  |  |  |  |  |
| Reporting irregular situations |  |  |  |  |  |
| Alarm indication |  |  |  |  |  |
| Statistics of equipment operation during drying |  |  |  |  |  |
| Recording consumption |  |  |  |  |  |
| Data archiving |  |  |  |  |  |
| Display | TFT | Graphical LCD | Character LCD + LED | Character LCD + LED | Character LCD + LED |
| Resolution | (800 x 480) | (240 x 128) | (20 x 4) | (20 x 4) | (20 x 4) |
| User interface | touch panel | keys | keys | keys | keys |
| | multilingual | multilingual | multilingual - latin | multilingual - latin, cyrillic | multilingual - latin |